New instaliation variant of Forteza FMC 10 and FMC 24 detectors on the fence

New instaliation variant of Forteza FMC 10 and FMC 24 detect...
Microwave sensors, FMC 10 and FMC 24 can be installed on the fence to detect the intruder, then he is trying to climb over the fence.
 




Special installation is  required using the brackets:
1) When we use FMC 24 detectors must be placed 350mm away from the fence.
2) When we use FMC 10, detectors must be placed 500mm away from the fence.
3) Mounting on the fence with bracket 120 mm.

NOTES:
-If you install a detector in more than 1.20 meters (4 feet) height you must reduce the length of detectors operation. Example: a) You need to protect 50 meters fence from climb over, so you have to use 100 meters detector. b)  You need to protect 100 meters, you have to use 200 meters detector.
-Before installation, all moving parts in detection zone must be removed.